AMTRA DIGITAL PH TESTER ATC – digital pH meter for the determination of pH in the aquarium
Features:
Practical digital tester for measuring the pH of water with automatic temperature compensation (ATC)
Integrated “automatic temperature compensation” ATC system
Possibility of re-calibration
Auto power off after a few minutes of inactivity
Hard plastic case included to be able to store it carefully
AMTRA DIGITAL PH TESTER ATC is an electronic pH meter that allows the rapid and precise determination of the pH of your aquarium water.
Practical “pen” shape to be carried and used anywhere. Possibility of automatic recalibration and temperature compensation are among the main advantages of this device suitable for both beginners and expert aquarists.
Instructions for Use:
Remove the protective cover of the electrode. Rinse the electrode with osmotic water and gently dry it with absorbent paper. Press [ON / OFF] to turn it on and insert the electrode into the solution to be tested. Move it gently in the water for about 30 seconds until the numbers on the display are stable and read the value. Switch off with [ON / OFF] (after 5 minutes of inactivity the instrument switches off automatically). Clean the electrode preferably with osmotic water and replace the lid before putting it back in the package.
AMTRA DIGITAL PH TESTER ATC is equipped with ATC system: automatic temperature compensation during measurement!
Calibration:
1. Turn on the pH meter and immerse the electrode in a standard buffer solution pH 6.86 (max 25 ℃)
2. Once the reading has stabilized, press the “CAL” button for 5 seconds (the instrument enters the automatic calibration state) wait until the display figure is 6.86 pH and remove it from the solution
3. Clean the electrode with osmotic water and dry gently with absorbent paper, then immerse the electrode in a standard pH 4.00 buffer solution.
4. Once the reading has stabilized, press the “CAL” button for 5 seconds, wait until the figure is 4.00 pH and remove it from the solution
5. Clean the electrode with osmotic water and then insert it in the standard solution pH 9.18: data between 9.17pH and 9.19pH are in the allowed error range. Calibration completed
Warning: The instrument must be recalibrated in the following conditions: after a long period of inactivity or after a long period of time since the last calibration, following frequent use or when high precision in measurement is required. Do not press the “CAL” button for a long time except to start the calibration otherwise the instrument must be recalibrated! If the electrode is exposed to air for a long time, it will dry out and the reading of the values will therefore be slow and not very stable. It is enough to immerse the electrode in osmotic water for a few hours to solve the problem.
Option 1
--
Recently Viewed
Subscribe to newsletter to receive news and updates
Choosing a selection results in a full page refresh.
Opens in a new window.
{"id":9711875457330,"title":"Amtra Digital PH Tester","handle":"amtra-digital-ph-tester","description":"\u003cdiv class=\"et_pb_module et_pb_wc_description et_pb_wc_description_0_tb_body et_pb_bg_layout_light et_pb_text_align_left\"\u003e\n\u003cdiv class=\"et_pb_module_inner\"\u003e\n\u003cp\u003e\u003cstrong\u003eAMTRA DIGITAL PH TESTER ATC – digital pH meter for the determination of pH in the aquarium\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_wc_description et_pb_wc_description_1_tb_body et_pb_bg_layout_light et_pb_text_align_left\"\u003e\n\u003cdiv class=\"et_pb_module_inner\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePractical digital tester for measuring the pH of water with automatic temperature compensation (ATC)\u003c\/li\u003e\n\u003cli\u003eIntegrated “automatic temperature compensation” ATC system\u003c\/li\u003e\n\u003cli\u003ePossibility of re-calibration\u003c\/li\u003e\n\u003cli\u003eAuto power off after a few minutes of inactivity\u003c\/li\u003e\n\u003cli\u003eHard plastic case included to be able to store it carefully\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_wc_tabs et_pb_wc_tabs_0_tb_body et_pb_tabs et_slide_transition_to_1\"\u003e\n\u003cdiv class=\"et_pb_all_tabs\"\u003e\n\u003cdiv class=\"et_pb_tab clearfix et-pb-active-slide\"\u003e\n\u003cdiv class=\"et_pb_tab_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eAMTRA DIGITAL PH TESTER ATC\u003c\/strong\u003e is an electronic pH meter that allows the rapid and precise determination of the pH of your aquarium water.\u003cbr\u003e\nPractical “pen” shape to be carried and used anywhere. Possibility of automatic recalibration and temperature compensation are among the main advantages of this device suitable for both beginners and expert aquarists.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement scale\u003c\/strong\u003e 0.00 – 14.00 pH +\/- 0.01pH\u003cbr\u003e\nATC (0 – 50 ° C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions for Use:\u003c\/strong\u003e\u003cbr\u003e\nRemove the protective cover of the electrode. Rinse the electrode with osmotic water and gently dry it with absorbent paper. Press [ON \/ OFF] to turn it on and insert the electrode into the solution to be tested. Move it gently in the water for about 30 seconds until the numbers on the display are stable and read the value. Switch off with [ON \/ OFF] (after 5 minutes of inactivity the instrument switches off automatically). Clean the electrode preferably with osmotic water and replace the lid before putting it back in the package.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAMTRA DIGITAL PH TESTER ATC\u003c\/strong\u003e is equipped with ATC system: automatic temperature compensation during measurement!\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e\u003cbr\u003e\n1. Turn on the pH meter and immerse the electrode in a standard buffer solution pH 6.86 (max 25 ℃)\u003cbr\u003e\n2. Once the reading has stabilized, press the “CAL” button for 5 seconds (the instrument enters the automatic calibration state) wait until the display figure is 6.86 pH and remove it from the solution\u003cbr\u003e\n3. Clean the electrode with osmotic water and dry gently with absorbent paper, then immerse the electrode in a standard pH 4.00 buffer solution.\u003cbr\u003e\n4. Once the reading has stabilized, press the “CAL” button for 5 seconds, wait until the figure is 4.00 pH and remove it from the solution\u003cbr\u003e\n5. Clean the electrode with osmotic water and then insert it in the standard solution pH 9.18: data between 9.17pH and 9.19pH are in the allowed error range. Calibration completed\u003cbr\u003e\nWarning: The instrument must be recalibrated in the following conditions: after a long period of inactivity or after a long period of time since the last calibration, following frequent use or when high precision in measurement is required. Do not press the “CAL” button for a long time except to start the calibration otherwise the instrument must be recalibrated! If the electrode is exposed to air for a long time, it will dry out and the reading of the values will therefore be slow and not very stable. It is enough to immerse the electrode in osmotic water for a few hours to solve the problem.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2024-11-28T19:28:30+01:00","created_at":"2024-11-28T19:28:32+01:00","vendor":"Croci","type":"","tags":["Croci","woo_import_1"],"price":2180,"price_min":2180,"price_max":2180,"available":true,"price_varies":false,"compare_at_price":2180,"compare_at_price_min":2180,"compare_at_price_max":2180,"compare_at_price_varies":false,"variants":[{"id":49571290513714,"title":"--","option1":"--","option2":null,"option3":null,"sku":"A3076617","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Amtra Digital PH Tester - --","public_title":"--","options":["--"],"price":2180,"weight":0,"compare_at_price":2180,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/naturepride.mt\/cdn\/shop\/files\/8023222196179.jpg?v=1732818515"],"featured_image":"\/\/naturepride.mt\/cdn\/shop\/files\/8023222196179.jpg?v=1732818515","options":["Option 1"],"media":[{"alt":null,"id":40181493727538,"position":1,"preview_image":{"aspect_ratio":1.778,"height":1080,"width":1920,"src":"\/\/naturepride.mt\/cdn\/shop\/files\/8023222196179.jpg?v=1732818515"},"aspect_ratio":1.778,"height":1080,"media_type":"image","src":"\/\/naturepride.mt\/cdn\/shop\/files\/8023222196179.jpg?v=1732818515","width":1920}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"et_pb_module et_pb_wc_description et_pb_wc_description_0_tb_body et_pb_bg_layout_light et_pb_text_align_left\"\u003e\n\u003cdiv class=\"et_pb_module_inner\"\u003e\n\u003cp\u003e\u003cstrong\u003eAMTRA DIGITAL PH TESTER ATC – digital pH meter for the determination of pH in the aquarium\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_wc_description et_pb_wc_description_1_tb_body et_pb_bg_layout_light et_pb_text_align_left\"\u003e\n\u003cdiv class=\"et_pb_module_inner\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePractical digital tester for measuring the pH of water with automatic temperature compensation (ATC)\u003c\/li\u003e\n\u003cli\u003eIntegrated “automatic temperature compensation” ATC system\u003c\/li\u003e\n\u003cli\u003ePossibility of re-calibration\u003c\/li\u003e\n\u003cli\u003eAuto power off after a few minutes of inactivity\u003c\/li\u003e\n\u003cli\u003eHard plastic case included to be able to store it carefully\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"et_pb_module et_pb_wc_tabs et_pb_wc_tabs_0_tb_body et_pb_tabs et_slide_transition_to_1\"\u003e\n\u003cdiv class=\"et_pb_all_tabs\"\u003e\n\u003cdiv class=\"et_pb_tab clearfix et-pb-active-slide\"\u003e\n\u003cdiv class=\"et_pb_tab_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eAMTRA DIGITAL PH TESTER ATC\u003c\/strong\u003e is an electronic pH meter that allows the rapid and precise determination of the pH of your aquarium water.\u003cbr\u003e\nPractical “pen” shape to be carried and used anywhere. Possibility of automatic recalibration and temperature compensation are among the main advantages of this device suitable for both beginners and expert aquarists.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement scale\u003c\/strong\u003e 0.00 – 14.00 pH +\/- 0.01pH\u003cbr\u003e\nATC (0 – 50 ° C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions for Use:\u003c\/strong\u003e\u003cbr\u003e\nRemove the protective cover of the electrode. Rinse the electrode with osmotic water and gently dry it with absorbent paper. Press [ON \/ OFF] to turn it on and insert the electrode into the solution to be tested. Move it gently in the water for about 30 seconds until the numbers on the display are stable and read the value. Switch off with [ON \/ OFF] (after 5 minutes of inactivity the instrument switches off automatically). Clean the electrode preferably with osmotic water and replace the lid before putting it back in the package.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAMTRA DIGITAL PH TESTER ATC\u003c\/strong\u003e is equipped with ATC system: automatic temperature compensation during measurement!\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e\u003cbr\u003e\n1. Turn on the pH meter and immerse the electrode in a standard buffer solution pH 6.86 (max 25 ℃)\u003cbr\u003e\n2. Once the reading has stabilized, press the “CAL” button for 5 seconds (the instrument enters the automatic calibration state) wait until the display figure is 6.86 pH and remove it from the solution\u003cbr\u003e\n3. Clean the electrode with osmotic water and dry gently with absorbent paper, then immerse the electrode in a standard pH 4.00 buffer solution.\u003cbr\u003e\n4. Once the reading has stabilized, press the “CAL” button for 5 seconds, wait until the figure is 4.00 pH and remove it from the solution\u003cbr\u003e\n5. Clean the electrode with osmotic water and then insert it in the standard solution pH 9.18: data between 9.17pH and 9.19pH are in the allowed error range. Calibration completed\u003cbr\u003e\nWarning: The instrument must be recalibrated in the following conditions: after a long period of inactivity or after a long period of time since the last calibration, following frequent use or when high precision in measurement is required. Do not press the “CAL” button for a long time except to start the calibration otherwise the instrument must be recalibrated! If the electrode is exposed to air for a long time, it will dry out and the reading of the values will therefore be slow and not very stable. It is enough to immerse the electrode in osmotic water for a few hours to solve the problem.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}